HPS Fusion TM
General Purpose Enclosed Transformers (Brochure link)
The HPS Fusion™ line of general purpose enclosed transformers are an indoor, cost effective approach ideally suited for single phase, general purpose industrial and light duty loads. Designed specifically for applications such as; signal and alarm systems, industrial lighting and circuit isolation, and HVAC applications.
The HPS Fusion general purpose transformer is enclosed in a TYPE 1 enclosure allowing for easy mounting and installation via four mounting slots and two keyhole slots. Removable covers provide easy access to the primary and secondary wiring compartments. Molded terminal blocks are on units up to 3000 VA and coil face terminations on units over 3000 VA. The HPS Fusion is CSA certified, UL listed, CE marked with a 15 year warranty.
|
 |
HPS SuperSentinel® (link to MFG site)
Super Energy Efficient General Purpose Transformers 1.2kV Class
Energy efficient K-factor transformers are designed to tolerate heating due to harmonics associated with non-linear loads. The HPS SuperSynergy will not only satisfy the necessity for running at K-Factor modern building load types, but in addition, because of the increasing need for energy conservation, they are much more efficient than that of our standard energy efficient line.
- Exceeds DOE 10 CFR Part 431 and (if applicable) CSA C802.2 efficiencies at 35% of rated load.
- Efficiency performance will meet the NEMA Premium® guidelines; 30% lower losses than DOE 10 CFR Part 431 and (if applicable) CSA C802.2 standards; when measured under a linear load profile.
|
 |
HPS SuperSynergy® (link to MFG site)
Super Energy Efficient K-Factor Transformers 1.2kV Class
The HPS SuperSynergy energy efficient K-factor transformer exceeds DOE 10 CFR Part 431 and (if applicable) CSA C802.2 effi ciencies over a range of linear loads. It is also designed to be used in a non-linear load environment running at a high K-factor. The HPS SuperSynergy helps satisfy the desire for increased energy conservation in addition to the required regulatory levels.
- Efficiency performance will meet the NEMA Premium® guidelines; 30% lower losses than DOE 10 CFR Part 431 and (if applicable) CSA C802.2 effi ciency standards; when measured under a linear load profile at 35% of rated load.
- Efficiency will meet or exceed DOE 10 CFR Part 431 and (if applicable) CSA C802.2 efficiency standards for linear load even at 50% of rated load when measured under a non-linear load up to K13.
|
 |
HPS SuperCenturion® (link to MFG site)
Super Energy Efficient Harmonic Mitigating Transformers 1.2kV Class
Specifically designed to treat the harmonics generated by computer equipment and other non-linear, power electronic loads. Combining zero sequence flux cancellation with phase shifting, treats 3rd, 5th, 7th, 9th, 15th, 17th and 19th harmonics within its secondary windings. Typical applications of severe non-linear loading conditions include data centers,
internet-service providers, telecom sites, call centers, broadcast centers, etc.
- Exceeds DOE 10 CFR Part 431 and (if applicable) C802.2 efficiencies at 35% of rated load.
- Efficiency performance will meet NEMA Premium® guidelines; 30% lower losses than DOE 10 CFR Part 431 and (if applicable) CSA C802.2 efficiency standards when measured under a linear load profile.
- Efficiencies will exceed DOE 10 CFR Part 431 and (if applicable) CSA C802.2 standards at an operating range from 35% to 65% of rated load when measured under a non-linear load profile up to K20.
|
 |
Energy Efficient Distribution Transformers (link to MFG site)
HPS offers three lines of energy efficient low voltage distribution transformers which meet or exceed the Canadian Energy Efficiency Regulations SOR/94-651 (and/or C802.2) efficiencies:
- Energy Efficient General Purpose Transformers
- Energy Efficient K-Factor Transformers
- Energy Efficient Harmonic Mitigating Transformers
|
 |
Encapsulated Distribution Transformers (link to MFG site)
HPS has two unique Encapsulated Distribution Transformer lines:
- HPS Titan series has been designed to operate in harsh environments and hazardous locations where safety is your priority, efficiency is a concern and the environment, location and application are key.
- HPS Fortress is an innovative design that provides the ideal solution for commercial applications where quality, ease of installation, and low cost are key.
|
 |
Autotransformers (link to MFG site)
HPS three phase autotransformers are available for applications where small voltage corrections are necessary in a distribution system. They are frequently used as an economical alternative to three phase general purpose distribution transformers to adjust the supply voltage to match specific load requirements when load isolation from the supply line is not required. Autotransformers can be used as either a step-up or step-down transformer.
|
 |
Control Transformers (link to MFG site)
Control transformers are isolation transformers designed to provide a high degree of secondary voltage stability (regulation) during a brief period of overload condition. Available in Open Core, Encapsulated Core, Enclosed and Enclosed Potted designs to fit any control application.
HPS offers Four lines of Control Transformers:
- HPS Spartan® Industrial Open Core and Coil Control Transformers
- HPS Imperator® Machine Tool Molded Control Transformers
- HPS Fusion enclosed indoor Control Transformers
- Q Series Enclosed Potted Control Transformers
|
 |
Low Voltage Lighting Transformers (link to MFG site)
For a cost effective approach to supply low voltage for Recreational, Lighting, Light Duty Industrial and Pool and Spa applications or for a general purpose load including actuating relays, bells, control and low voltage circuits. HPS single phase encapsulated (NEMA 3R) control transformers, with ratings from 50VA up to 5000VA in three voltage ratings, feature the newest technology and manufacturing processes.
|
 |
Line Reactors - RM Series (link to MFG site)
By choosing a HPS line reactor, many line problems can be eliminated. Additionally, performance, life expectancy and efficiency of both the motor and the drive itself are significantly enhanced.
HPS offers two lines of Line Reactors:
- RM Series Line Reactors
- RC Series DV/DT Filter Reactors
|
 |
Energy Efficient Drive Isolation Transformers (link to MFG site)
HPS Drive Isolation Transformers are designed to meet the rugged demands of both AC and DC variable speed drives, and also provide the required voltage change. The separate primary and secondary windings provide electrical isolation between the incoming line and the SCR load. The windings are designed to withstand overcurrent of 150% of the rated load for 60 seconds or 200% of the rated load for 30 seconds.
Drive Isolation Transformers are sized to match standard motor horsepower and voltage ratings. Standard sizes range from 5 to 600 HP in six standard voltages and available in Standard and Energy Efficient designs.
|
 |
Dry Type Medium Voltage Transformers (link to MFG site)
HPS Dry-Type Medium Voltage (Power) Transformers are regarded for their high level of quality and service reliability that has become synonymous with HPS transformer products. With three phase ratings up to 34 MVA, 46 kV, 250 kV BIL and single phase to 5 MVA, we feature the newest technology and manufacturing processes. |
 |
Energy Efficient General Purpose Medium Voltage Distribution Transformers (link to MFG site)
HPS Millennium™ energy efficient general purpose medium voltage distribution transformers are rated for 600 volts and up. They are designed for stepping down incoming higher voltage power to utilize voltages for commercial, institutional or industrial applications. The standard NEMA 3R ventilated construction is ideally suited for indoor or outdoor applications. |
 |
Buck boost Transformers (link to MFG site)
Buck-boost transformers offer an economical solution to the adjustment of line voltages that are slightly above or below normal. When a buck-boost transformer is connected as an autotransformer, only a portion of the load kVA is actually transformed. The majority of the load kVA is passed directly through to the source. For this reason a buck-boost transformer may be used to supply a much larger kVA load than is indicated on the nameplate. Buck-boost transformers can be used to adjust stable voltages only.
|